GSTM1 Polyclonal Antibody
Price:
Size:
100μL
50μL
- 宿主: Rabbit
- 反应性: Human;Mouse;Rat
- 应用性: WB;IHC;IF
Verified Samples |
Verified Samples in WB:Rat heart Verified Samples in IHC:Human kidney Verified Samples in IF:NIH-3T3,C6 |
Clonality | Polyclonal |
Isotype | IgG |
Immunogen | Recombinant Mouse GSTM1 protein expressed by E.coli |
Abbre | GSTM1 |
Synonyms | Glutathione S-transferase Mu 1;EC:2.5.1.18;GST 1-1;GST class-mu 1;Glutathione S-transferase GT8.7;pmGT10;Gstm1 |
Swissprot | |
Calculated MW | 25kDa |
Observed MW | 26kDa |
Concentration | 1mg/mL |
Storage | Store at -20°C Valid for 12 months. Avoid freeze / thaw cycles. |
Buffer | PBS with 0.02% sodium azide,50% glycerol pH 7.4 |
Purification Method | Antigen Affinity Purification |
Conjugation | Unconjugated |
Background | Cytosolic and membrane-bound forms of glutathione S-transferase are encoded by two distinct supergene families. At present,eight distinct classes of the soluble cytoplasmic mammalian glutathione S-transferases have been identified: alpha,kappa,mu,omega,pi,sigma,theta and zeta. This gene encodes a glutathione S-transferase that belongs to the mu class. The mu class of enzymes functions in the detoxification of electrophilic compounds,including carcinogens,therapeutic drugs,environmental toxins and products of oxidative stress,by conjugation with glutathione. The genes encoding the mu class of enzymes are organized in a gene cluster on chromosome 1p13.3 and are known to be highly polymorphic. These genetic variations can change an individual's susceptibility to carcinogens and toxins as well as affect the toxicity and efficacy of certain drugs. Null mutations of this class mu gene have been linked with an increase in a number of cancers,likely due to an increased susceptibility to environmental toxins and carcinogens. Multiple protein isoforms are encoded by transcript variants of this gene. |
Western blot with GSTM1 Polyclonal antibody at dilution of 1:1000.lane 1:Rat heart
Immunohistochemistry of paraffin-embedded Human kidney using GSTM1 Polycloanl Antibody at dilution of 1:600
Immunofluorescence analysis of NIH-3T3 cells using GSTM1 Polyclonal Antibody at dilution of 1:200
Immunofluorescence analysis of C6 cells using GSTM1 Polyclonal Antibody at dilution of 1:200
E-IR-R217 | 2-step plus Poly-HRP Anti Mouse/Rabbit IgG Detection System (with DAB solution) | 18mL , 6mL , 3mL |
E-IR-R220 | Super PlusTM Highly Sensitive and Rapid Immunohistochemical Kit (pH9.0) | 10mL , 3mL |
E-IR-R221 | Super PlusTM Highly Sensitive and Rapid Immunohistochemical Kit (pH6.0) | 10mL , 3mL |
E-IR-R304A | Western Blot Detection Kit | 50Assays |
E-IR-R304B | High Accuracy and Absorbability Western Blot Detection Kit | 50Assays |